Home > Products >SZS series gas-fired (oil-fired) steam boiler
SZS series gas-fired (oil-fired) steam boiler

SZS series gas-fired (oil-fired) steam boiler

SZS series gas-fired (oil-fired) steam boiler

SZS series gas-fired (oil-fired) steam boiler

Product thermal capacity:10-100 t/h

Working pressure:2.5-9.8 Mpa

Available fuel:Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.

Available industries:Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc

Send E-mail:allen@zozen.com

Join Us On Whatsapp:Click it to Join in

Introduction to SZS series gas-fired (oil-fired) steam boiler

SZS series boiler is designed with longitudinal double drums and " D " type chamber structure. Furnace is placed on the right and convection tube bank is on the left, super heater is arranged at convection tube bank. The body is fixed on the basement by middle and both end flexible supports and make the boiler expand horizontally sideways. Around the furnace is membrane water cooling tube wall. Furnace and tube bank are totally separated by the membrane water tube cooling wall at the left side of the furnace. The back part of bundle is sparse shift structure, front part is aligned structure. Smoke from furnace outlet enters re-burning chamber, convection tube bank area and then from left front part enters spiral fine coil economizer and condenser, and finally is discharged to atmosphere through chimney.

Technical Features

Safety
  • Boiler body uses the forced circulation in the high temperature area to make sure all heating areas can be cooled down and avoid vaporization; The explosion door and flame detector are equipped for safe and reliable operation. Comb plates are used between both sides of boiler and tube bundle to avoid leakage of condensate and gas caused by using refractory concrete as sealing material. Air proof test is done before delivery in the factory to guarantee any gas leakage problem.

Environmental protection
  • Big combustion chamber equipped with Low emission combustion burner effectively reduce the NOx to 30mg/m3. Smoke duct and smoke outlet use internal insulation to reduce operating noise.

  • Combustion chamber uses full membrane water cooling wall structure and pressurized combustion without smoke mixture. 

Energy conservation
  • Good quality alumina silicate fiber and fire clay insulation material are used and the boiler body temperature is controlled below 45℃ and greatly heat loss is  reduced. Combustion chamber is designed with narrow distance tube membrane water cooling wall which has good air proof to reduce heat lost and increase boiler thermal efficiency. Internal inspection holes uses high-alumina refractory and manhole cover seal devices, solving superheat problem in this part caused by using refractory bricks.

Convenience
  • Manholes are placed on the front and back side of drums and inspection doors on back side of boiler easy to open for inspection and clean inner and outer parts.

longer lifespan
  • Membrane structure are used in the front and back wall for boiler body and highly increased their lifespan to over 20 years.

  • The key processes including material cutting, rolling, drilling are done by advanced CNC machining process to reduce the assembly stress and extend boiler service lifetime.

  • Flutter prevention fastener is used for high temperature part convection tubes, which avoid convection tube cracking problem.

  • Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will be tested by radiographic inspection.

Show more

Technical data

Model Rated evaporation(t/h) Rated working pressure(MPa) Rated steam temperature(℃) Thermal efficiency(%)
SZS20-1.25-Q.Y 20 1.25 194 >98
SZS20-1.6-Q.Y 20 1.6 204 >98
SZS20-2.5-Q.Y 20 2.5 225 >98
SZS25-1.25-Q.Y 25 1.25 194 >98
SZS25-1.6-Q.Y 25 1.6 204 >98
SZS25-2.5-Q.Y 25 2.5 225 >98
SZS30-1.25-Q.Y 30 1.25 194 >98
SZS30-1.6-Q.Y 30 1.6 204 >98
SZS30-2.5-Q.Y 30 2.5 225 >98
SZS35-1.25-Q.Y 35 1.25 194 >98
SZS35-1.6-Q.Y 35 1.6 204 >98
SZS35-2.5-Q.Y 35 2.5 225 >98
SZS40-1.25-Q.Y 40 1.25 194 >98
SZS40-1.6-Q.Y 40 1.6 204 >98
SZS40-2.5-Q.Y 40 2.5 225 >98
SZS50-1.25-Q.Y 50 1.25 194 >98
SZS50-1.6-Q.Y 50 1.6 204 >98
SZS50-2.5-Q.Y 50 2.5 225 >98
SZS65-1.25-Q.Y 65 1.25 194 >98
SZS65-1.6-Q.Y 65 1.6 204 >98
SZS65-2.5-Q.Y 65 2.5 225 >98
SZS75-1.25-Q.Y  75 1.25 194 >98
SZS75-1.6-Q.Y 75 1.6 204 >98
SZS75-2.5-Q.Y 75 2.5 225 >98
SZS100-1.25-Q.Y  100 1.25 194 >98
SZS100-1.6-Q.Y 100 1.6 204 >98
SZS100-2.5-Q.Y 100 2.5 225 >98

 

Send Inquiry

We guarantee that your information will not be divulged to third parties and reply to you within 24 hours.

Please enter your demand such as Raw material type, Capacity, Feeding material size, Final product size, etc. To become our quality clients will have access to a discount of contract!

  • Product Name(*)
  • Your Name
  • Your Email
  • Your Phone/Whatsapp*
  • Requirements

Contact us

Our sales team is available to respond to any queries you might have on HXJQ. Get in touch using the details below:

address: No.8, Tanxiang Road, Zhengzhou, Henan, China.

Email:allen@zozen.com

Contact Us Quickly
  • Your Name
  • Your Email*
  • Your Phone
  • Your Message*
Related Products
WNS series gas-fired (oil-fired) steam boiler
SZS series gas-fired (oil-fired) hot water boiler
WNS series gas-fired (oil-fired) hot water boiler
SZS series gas-fired (oil-fired) steam boiler
DZL series coal-fired steam boiler
DHL series coal-fired steam boiler
SHX coal-fired CFB (circulating fluidized bed) steam boiler
DHX coal-fired CFB (circulating fluidized bed) steam boiler
SZL series coal-fired steam boiler
DZL series coal-fired hot water boiler
DZL series biomass-fired steam boiler
DHX coal-fired CFB (circulating fluidized bed) hot water boiler
SZL series coal-fired hot water boiler